2.2.1 ELECRICAL ADJUSTMENT
TOP
PREVIOUS
NEXT
ITEM
CONDITION/ PRESET
SIGNAL INPUT or TEST Chart
TEST POINT
HOW TO ADJUSTMENT & SPEC
1/Maximum Charge control voltage
Refer to
Fig.1
AC in
IC203-Pin1
Connect the Digital Volt Meter to IC203-Pin1.
Connect the AC cable to AC soket.
Then adjust the VR201 so that the DC voltage at IC203-Pin1 become
8.30±0.1Vp-p
.
Fig.1
@
TOP
PREVIOUS
NEXT