smartctl 6.5 2016-05-07 r4318 [i686-w64-mingw32-xp-sp2] (sf-6.5-1) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: SAMSUNG SpinPoint P80 Device Model: SAMSUNG SP0842N Serial Number: S0WFJ90P502109 Firmware Version: BH900-41 User Capacity: 80 026 361 856 bytes [80,0 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a Local Time is: Tue Jul 11 21:57:47 2017 PM ==> WARNING: May need -F samsung2 or -F samsung3 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF ENABLE/DISABLE COMMANDS SECTION === SMART Enabled. === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 1803) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 30) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 253 100 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0007 100 100 025 Pre-fail Always - 4288 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 11 5 Reallocated_Sector_Ct 0x0033 253 253 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x000f 253 253 051 Pre-fail Always - 0 8 Seek_Time_Performance 0x0025 253 253 015 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 253 253 000 Old_age Always - 5 10 Spin_Retry_Count 0x0033 253 253 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0012 253 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9 187 Reported_Uncorrect 0x0032 253 253 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 142 106 000 Old_age Always - 32 194 Temperature_Celsius 0x0022 142 106 000 Old_age Always - 32 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 24213 196 Reallocated_Event_Count 0x0032 253 253 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 253 253 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 253 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000a 253 100 000 Old_age Always - 0 201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.